RCooling Full Inverter In-row Air Conditioner
The rCooling row-type data center air conditioner has been identified by the Jiangsu Provincial Department of Science and Technology as a high-tech product. It is a rack-level cooling, high-efficiency, and energy-saving precision air conditioner for data centers. Suitable for micro-modular data centers with high temperature or humidity control accuracy and sensible heat requirements. The rCooling full-frequency conversion row-type air conditioner is placed within the rack array and installed side-by-side with the server cabinets. Air is discharged from the front of the unit and returned from the rear, close to the heat source, with near-end cooling for high cooling efficiency; The rCooling full series has air-cooled/water-cooled types (cooling capacity 25~60kW), which can meet the environmental control needs of various data centers in different regions. All air-cooled products are equipped with variable frequency compressors, precisely matching the cooling capacity with the load, resulting in significant energy savings.
Application Scenarios
rCooling full-variable frequency row-spacing air conditioners are mainly suitable for
(1) Data centers and computer rooms with high heat density and low PUE requirements;
(2) Such as supercomputing centers, data centers, cloud computing centers, communication rooms, switching rooms, transmission rooms, and electronic information system rooms;
(3) Integrated micro-modular data centers;
(4) Precision environments such as container data centers;
Features and Value
Leading technology, safe and reliable
▪ Adopts permanent magnet synchronous DC brushless variable frequency compressor, with low noise and small vibration, capable of automatically adjusting cooling output according to changes in server room load;
▪ The compressor adopts a low-pressure chamber design, ensuring high reliability, with a dual flexible scroll design for both axial and radial directions
Reliable quality, stable operation
▪ High-performance DC/EC centrifugal fan, large air volume, high static pressure, stable operation, low noise;
▪ Fully enclosed electronic expansion valve control, precise regulation, ensuring stable refrigerant flow and reducing temperature fluctuations in the server room;
▪ The outdoor fan adopts stepless speed regulation technology to ensure stable operating pressure and reduce unit energy consumption
Intelligent Control
▪ Adopts intelligent controller for PID calculation, automatically adjusting compressor and fan speeds;
▪ Standard RS485 communication interface, enabling coordinated linkage with external equipment, helping the entire server room air conditioning system achieve intelligent and energy-saving control