Heat Pipe Air Conditioning UnitHeat Pipe(DZ High-Density Multi-Connected Heat Pipe Air Conditioning Unit)
Canatal developed heat pipe air conditioning units mainly include end products such as inter-row, back-panel, top-mounted, and ceiling-mounted types, as well as air-cooled, water-cooled, and chilled water heat pipe host products. The heat pipe air conditioning units, used in conjunction with conventional computer room air conditioners, can solve the heat dissipation problems of individual cabinets in high-heat-density computer rooms, ranging from 5 to 30 kW, and address local hot spots. Jialitu heat pipe air conditioners utilize the principle of separated heat pipes, achieving closed-loop circulation within the heat pipe system through refrigerant phase change and natural gravity, or relying on the mechanical power of a Freon pump for circulation in the case of long pipelines.
Inter-row and back-panel heat pipe terminals support single or double coil configurations, and power/gravity heat pipes; heat pipe host products integrate a Freon pump and heat exchanger, and can be matched with air-cooled, chilled water, and water-cooled cooling sources. Heat pipe terminal products are closer to the heat source of the server cabinet, resulting in lower cold loss, higher cooling efficiency of the refrigerant, and can also be used with VRH composite multi-link heat pipe natural cooling host units.
The cooling capacity range of heat pipe terminal products is 3~40 kW, and the refrigeration capacity range of heat pipe host products is 61.5~401.5 kW.
Application Scenarios
Heat pipe air conditioning units are energy-efficient and resource-efficient technology products suitable for new data center machine rooms and energy-saving renovations of existing data centers. They can be used in small, medium, large, and ultra-large data centers. In high-heat-density machine rooms, heat pipe air conditioning units serve as an effective supplement to conventional machine room air conditioners, efficiently solving the problems of "hot spots" and "hot zones" in the machine room.
Such as supercomputing centers, data centers, cloud computing centers, liquid-cooled data centers, and newly built data centers in government, education, banking, securities, insurance, communications, Internet of Things, transportation, and energy industries, including main machine rooms, high-heat-density machine rooms, communication machine rooms, transmission machine rooms, aggregation machine rooms, 5G base stations, switching machine rooms, mobile machine rooms, computer rooms, and electronic information system machine rooms.
|
End-type |
Application Scenarios |
|
Inter-row End |
Single cabinet 5kW and above, new or renovation projects, mostly new machine rooms. Requires use with enclosed aisles. |
|
Ceiling End |
Used for renovation projects where conditions for installing inter-row air conditioners are poor, and the area above the aisle is relatively open, allowing for installation above the aisle. |
|
Top-mounted End |
Single cabinet power exceeding 5kW, with relatively open space above the cabinet, making it convenient to install a top-mounted end. |
|
Back Panel End |
Single cabinet 5-15kW, used for new or renovation projects. Does not require enclosed aisles, saving on aisle investment. |
Features and Value
Heat pipe end
▪ Flexible and diverse
Flexible installation methods, including inter-row, backplane, suspended ceiling, and top-mounted types. Both powered and gravity heat pipes are available.
▪ Safe and reliable
Uses Freon as the refrigerant, eliminating water in the machine room; multiple fan configurations allow for zonal control.
▪ High sensible heat ratio
Sensible heat ratio of 100%, no condensate, avoiding energy loss from latent cooling.
▪ Close to the heat source
Close to the cabinet air supply, saving on supply fan power consumption.
▪ Intelligent control
Excellent human-machine interface, advanced intelligent control technology, standard RS485 communication interface for easy remote monitoring.
Heat pipe host
▪ Flexible layout
Small unit size, can be placed outside the machine room, saving machine room air conditioning space.
▪ Highly efficient and energy-saving, stronger applicability
Adjustable unit cooling capacity, easy to expand, high part-load efficiency.
▪ Safe and reliable
Dual refrigerant pumps, backup operation.
Dew point temperature control, ensuring no condensate is produced at the end.