Single-phase immersion liquid cooling

The heat storage capacity of coolant is 1000+ times that of air, and the heat transfer rate is 20+ times that of air. Due to the excellent thermodynamic properties of the coolant, the overall heat exchange efficiency is high, the fluid temperature field is stable, there are no local hot spots, and a single cabinet can accommodate higher equipment power. The acceleration of the digital process and the "dual carbon" commitment have made the construction of green data centers a major trend. Liquid cooling technology, with its advantages of energy saving, environmental protection, safety, and low carbon emissions, has the potential to become an important cooling technology in the future.

Currently common liquid cooling methods include cold plate, spray, single-phase immersion, and phase-change immersion. Single-phase immersion liquid cooling technology, as a cross-generational technology that subverts traditional air cooling technology, immerses IT equipment in a dielectric fluid, completely separating it from air, to ensure that IT equipment is protected from harsh environments. Compared with air cooling, it has stronger heat dissipation capacity; compared with cold plate, it achieves 100% heat removal by liquid cooling; compared with spray, it has higher cleanliness without drift; and compared with phase-change immersion, it does not need to consider the strict sealing problems brought about by phase change.

Jialitu's single-phase immersion liquid cooling series products are designed for synthetic oil coolant application scenarios and are compatible with 19-inch servers/21-inch servers/BBUs, etc. The single CDU heat exchange capacity ranges from 20 kW to 80 kW, and the TANK capacity ranges from 21U to 42U.

Application Scenarios

Large data centers: High PUE requirements;

Communication machine room: High power, high density, difficult heat dissipation

Edge computing node: Multi-point collaboration, simple site selection

Liquid-cooled container data center: Rapid deployment, ultra-high density

Features and Value

Energy-efficient

▪ PUE<1.08, achieving ultra-low energy consumption and high-efficiency heat exchange, effectively saving 30%~40% electricity;

▪ Breaking through the heat dissipation bottleneck of single cabinets under traditional air cooling, the TANK can achieve a maximum heat dissipation density of 2kW/U, improving land utilization rate per unit area, and saving up to 70% of the floor space.

Safe and Reliable

▪ Immersion liquid cooling isolates air, reducing IT failure rate by 53%;

▪ System dual-redundancy design, transient intelligent switching, high backup;

Low Environmental Dependency

▪ Immersion liquid cooling can adapt to any climate conditions, can be deployed in white space, without considering airflow organization, realizing site selection free from geographical, spatial, and environmental limitations.