CAHU-R series heat pipe air curtain
The CAHU-R series heat pipe air wall unit can be equipped with a VRH multi-air conditioning system. The air wall-type heat pipe terminal cooling capacity ranges from 30-50kw, using R410A refrigerant, with a cooling capacity ranging from 8200-13500m³/h, providing a highly efficient and energy-saving thermal management solution for data centers. Deeply integrating heat pipe heat transfer technology and air wall structure, it achieves precise temperature control in high heat flux density scenarios in the machine room. The core of the heat pipe terminal lies in utilizing the phase-change heat transfer characteristics of the heat pipe and the active air supply of the fan to work together, achieving low energy consumption, high reliability, and precise heat dissipation, especially suitable for areas rich in natural cold sources or scenarios with strict energy-saving requirements.
Application Scenarios
Areas rich in natural cold sources: such as Northern Europe and the Yunnan-Guizhou Plateau, where heat pipes can dissipate heat for 80% of the year;
Renovation of old data centers: Enhancing cooling capacity without expanding power capacity;
Hybrid cooling architecture: Working with liquid cooling backplanes to handle high-density loads of 30kW+/cabinet;
Features and Value
Refrigeration Efficiency Innovation
▪ Innovative coupling of heat pipe technology and wind wall technology. Heat pipes actively absorb heat using the principle of phase change heat transfer, while the wind wall uses fans for convective heat exchange.
▪ Energy-efficient operation throughout the year. In temperate regions, heat pipes can operate independently for 2500-4000 hours/year, making full use of heat pipe characteristics and natural cold sources.
Space-saving Design
▪ Modular design achieves a tightly coupled layout of "cabinet as heat dissipation," saving more than 40% of data center space and supporting hot-swappable maintenance.
▪ Rapid deployment and controllable costs. Heat pipe sections and wind walls are pre-assembled; on-site installation only requires connecting air ducts and refrigerant pipes, reducing installation time by 60% compared to traditional air conditioning.
Flexible Deployment Design
▪ Compatible with vertical or horizontal air supply modes. The vertical wind wall delivers cold air from the bottom of the cabinet and exhausts hot air from the top, suitable for cold/hot aisle containment systems. The horizontal wind wall delivers cold air horizontally from the front of the cabinet, suitable for open spaces or modular data centers.
▪ The outdoor unit is equipped with a Jali VRH system heat pipe multi-unit host to achieve multi-unit adaptability.